HD ultrafiltration rate calculator

mL/kg/h, and the time needed to stay under 13 · Dialysis & CRRT

Educational use · for healthcare professionals and trainees · not for time-critical decisions · verify every result

When to use it

mL/kg/h, and the time needed to stay under 13.

Inputs

  • Pre-dialysis weight (kg)
  • Target (dry) weight (kg)
  • Session length (hours)
  • Rinse-back + intake (mL)

Formula

UF rate = (pre − target weight + extra) / hours / target weight.

Interpreting the result

Example with the app's default inputs:

  • Total UF goal 3.8L (information)
  • UF rate 12.1mL/kg/h (caution)
  • Time to stay ≤13 mL/kg/h 3.72hours (information)

Interpretation: Between 10 and 13: watch for cramping and hypotension.

References

Formula Reviewed Oct 2026 · v1

FAQ

What is the HD ultrafiltration rate used for?

mL/kg/h, and the time needed to stay under 13.

What inputs does it need?

Pre-dialysis weight (kg); Target (dry) weight (kg); Session length (hours); Rinse-back + intake (mL).

How is it calculated?

UF rate = (pre − target weight + extra) / hours / target weight.

What is it based on?

Flythe JE et al. Kidney Int 2011;79:250–257 (PMID 20927040).

Is this medical advice?

Educational use only. Not medical advice; does not replace clinical judgment or institutional protocols. Verify all drug doses. Educational use · for healthcare professionals and trainees · not for time-critical decisions · verify every result.

Related calculators

All calculators and workups

Educational use only. Not medical advice; does not replace clinical judgment or institutional protocols. Verify all drug doses.

Educational use only. Not medical advice; does not replace clinical judgment or institutional protocols. Verify all drug doses. ·